Rheumatoid Wrist Arthroplasty & Arthrodesis - Naffis Anjarwalla 9/1/2001
Brief
|
O' Driscoll JHS(A) 1992
|
Authors
|
O'Driscoll S.W. Horii E. Ness R. Cahalan T.D. Richards R.R.
|
Title
|
The relationship between wrist position, grasp size, and grip strength.
|
Reference
|
JHS 17(A) 169-177 1992
|
Summary
|
Maximal wrist strength is n greater extension than recommended for fusion. This is to allow for function. Getting 2/3 power post fusion should be considered v.good
|
Critique
|
Good on wrist position, but only 20 people so not really powerful on the size comparison. Appreciate probs of function and pt satisfaction.
|
Brief
|
Jolly JHS 17(A) 1992
|
Authors
|
Jolly S.L. Ferlic D.C. Clayton M.L. Dennis D.A. Stringer E.A.
|
Title
|
Swanson silicone arthroplasty of the wrist in rheumatoid arthritis: A long term follow up
|
Reference
|
J of Hand Surgery 17(A) 142-15 1992
|
Summary
|
28 retrospective review 5yrs, 26% revision , 52% fracture rate, 30% silicon reaction. Reasonable option in the very degenerate wrist
|
Critique
|
High rate of complication with prosthesis make this a good report.
|
Please log in to view the content of this page. If you are having problems logging in, please refer to the login help page.
|